Re: light sources and Pt/Pd prints

Date view Thread view Subject view Author view

From: Jeffrey D. Mathias (jeffrey.d.mathias@worldnet.att.net)
Date: 05/04/00-05:37:14 AM Z


Kerik717@aol.com wrote:
> What did your sensitizer consist of?

12.76 grams Ferric Oxalate powder (98% pure)
1.50 grams Oxalic Acid
0.50 grams EDTA (CAS: 60-00-4)
distilled water to make 50 ml

This makes a 25% solution to be used with the appropriate metal
solutions.

Although I will be changing to 0.25 grams EDTA (0.5%) and recommend this
(once tested) as this amount should be sufficient to assist clearing and
an excess of EDTA causes the metal to "float" through the paper (this is
noticed as a "bleeding" of the metal through or off the paper.) This
effect is very noticeable when using 2% EDTA.

-- 
Jeffrey D. Mathias
http://home.att.net/~jeffrey.d.mathias/


Date view Thread view Subject view Author view

This archive was generated by hypermail 2b29 : 06/13/00-03:10:16 PM Z CST