Re: Optimum AFO sensitizer % for Ziatype

From: Jeffrey D. Mathias ^lt;jeffrey.d.mathias@att.net>
Date: 10/11/04-08:58:52 PM Z
Message-id: <416B486C.8090402@att.net>

Loris Medici wrote:

Loris Medici wrote:
> Molecular Weight of Li2PdCl4 is = 262.1128
> Molecular Weight of AFO is = 374.0187
> So, when doing Ziatypes, if I want to use a 40% AFO sensitizer -
> assuming there should be about equal amnt. of sensitizer and metal
> molecules in the coating solution - the % of Li2PdCl4 solution should
> be:
> 0.40 x 262.1128 / 374.0187 = 0.280320... = 28.03%
> Is this correct? ...

No.
The molar mass of AFO is 428.06
0.40 x 262.11 / 428.06 = 0.2449
or 24.49%

My study made the following recomendation (for certain papers):
AFO made as a 35% solution.
Li2PdCl4 made as a 21.43% solution.
Na2PdCl4 made as a 24.05% solution.
K2PdCl4 made as a 26.7% solution.
K2PtCl4 made as a 33.9% solution.

Notes: The metal solutions may be mixed and switched. Some of the metal
solutions may have to be heated to be totally in solution or coated as
suggested by my quasi multi-coat method.

-- 
Jeffrey D. Mathias
http://home.att.net/~jeffrey.d.mathias/
Received on Mon Oct 11 21:07:03 2004