http://www.loris.medici.name/images/ziatype-first-print.jpg
(This is the cropped version, the original is 11"x11" square format; the
scanner wasn't big enough to scan the print as one piece)
* The digital negative was printed on Photowarehouse Ultrafine transparency
using Conetech Selenium Piezotone quadblack inks.
* Paper was Whatman HP treated with 1.5% oxalic acid (which seems to not
change anything; dmax didn't improved. So, I probably won't use oxalic acid
anymore - now it looks like a loss of time to me).
* Used 2ml coating solution to coat an 11"x11" area (20% less than Clay's
recommendation of 0.2ml per 10 square inches), used a 40mm Magic Brush.
Coating solution was: 25 drops AFO, 25 drops Li2PdCl4 and 1 drop 1.5%
Ammonium Dichromate.
* Exposed for 2:30 using 40W Philips actinic fluorescent lightbulbs placed
2" above the printing frame glass.
* Developed in 2-4% citric acid.
The print has some white spots due to the damaged negative (there were
stucked paper fibers on the negative - because the previous trial was
exposed too early!). How I can spot these?
Thanks to those who provided helpful and valuable information.
Regards,
Loris.
Received on Sat Oct 16 11:13:08 2004
This archive was generated by hypermail 2.1.8 : 11/03/04-10:51:23 AM Z CST